Product: YT10
|
|
|
|
|
|
|
|
Features
|
|
- High accuracy and high reliability
- Airproofed structure with high stability
- Small volume, light weight and very convenient to use
- Suitable for precision measuring of all kinds of static states or the no-crystal liquid, gas and the high capacity pressure measurement that changes very slowly.
|
|
|
|
|
|
Specifications
|
Capacity
|
MPa
|
0.6,0.8,1,1.5,2,3,4,5,6,8,10,12,15,20
|
|
Bar
|
6,8,10,15,20,30,40,50,60,80,100,120,150,200
|
|
Non-linearity
|
%FS
|
0.1, 0.2, 0.3
|
|
Repeatability
|
%FS
|
0.1, 0.2, 0.3
|
|
Hysteresis
|
%FS
|
0.1, 0.2, 0.3
|
|
Temperature effect on zero
|
%FS/10℃
|
0.1, 0.2, 0.3
|
|
Temperature effect on span
|
%FS/10℃
|
0.1, 0.2, 0.3
|
|
Terminal Resistance,output
|
Ω
|
350+3
|
|
Insulation Resistance
|
MΩ
|
1000(100VDC)
|
|
Output Sensitivity
|
mV/V
|
1.5+0.2
|
|
Zero Balance
|
mV
|
≤+1 |
|
Excitation,recommended
|
V
|
9-12(DC/AC) |
|
Excitation,permition
|
V
|
6-18(DC/AC) |
|
Temperature,compensated
|
℃
|
-10-+50 |
|
Temperature,operating
|
℃
|
-20-+65 |
|
Safe Overload
|
%FS
|
120 |
|
Ultimate Overload
|
%FS
|
150 |
|
outline dimensions(mm) Note:
- When installing please use the flat end airproofed connector with the screw thread of M14*1.5,inside wimble is 37°(If the customers need the connector with other screw thread, please give the special order to the company).
- The medium material that meets: Titanium-alloy.
- The pressure transducers are connected with indicator through sockets.
|
|